Canadian Water Technologies, Calgary, AB

CWT-Design, Manufacturing, Installation, Service

DEIONIZATION SERVICE

Premium Grade Service
Exchange Deionizers

Canadian Water Technologies, Calgary - Premium Grade Service - Exchange Deionizers

Superior Silica and Heavy Metals Removal
PG Type 1 resins have a higher basicity and a uniform bead size that makes them more effective than common Type 2 gel resins. As a result, they remove more silica than any other resin. In addition, all premium grade deionizers are guaranteed to produce 18 megohm/cm, initially and after each regeneration service.

Quality Controlled Resin Selection
Each lot of resin from the manufacturer is carefully inspected by CWT's quality control specialists. Only resins of the highest quality are used in CWT's deionizers to ensure that water quality will not be compromised.

Premium Grade Resins are Specially Regenerated
The unique structure of CWT's PG DI resin, requires a special process to achieve effective regeneration. In addition to the procedures and precautions used in the high purity deionization resin regeneration process, anion resins are flushed with a heated caustic solution. This drives off retained silica and organics from all surface areas of the resin. Lastly, all resins are rinsed with 18 megohm water and repacked with a unique air mixing system to ensure the proper anion/cation mix throughout each tank.

Line Pressure Operated
System operates on tap pressure, within a pressure range of 25-60 psi. Mixed bed deionizers will produce from 3/4 to 15 gallons per minute. Higher flow rates may be obtained by installing multiple tanks in a parallel configuration.

No User Maintenance
CWT assumes all responsibility for timely exchange of exhausted deionizer tanks. Specially designed flexible hoses with quick-disconnect fittings ensure minimum downtime.

Service When You Need It
In critical applications, CWT will exchange your tanks within 24 hours of your phone call. Service contracts can be arranged to suit your specific requirements.

 

 Max. Feed Water Parameters
Design Pressure: 40 psig
Temperature: 100 °F (38°C)
Turbidity: 5 NTU
Colour: 5 Units
Organics: 3 ppm
Manganese and Iron: 0.3 ppm
Free Chlorine: 0.2 ppm
Total Dissolved Solids: 500 ppm

  Accessories
Pre/Post Filters (10-0.2 Micron)
Activated Carbon Filters
Water Quality Indicator Lights
Audible Alarms
Remote Monitors
Ultraviolet Sterilizers
Recirculation Pumps
 

 

Contact our office for more information on these components.

Deionization Services

[Water Treatment Systems] [FilmTec™ ;Membranes] [Deionization] [HOME] [Links] [About Us] [Components] [Project Photo Gallery]   
[Site Map]

© 2011 Canadian Water Technologies Ltd.
Site by: RGW & Associates, Inc. E-mail at: RGWGraphicStudio@shaw.ca



Water Treatment Systems FILMTEC Membranes Deionization CWT HOME Page Useful Links About Canadian Water Technologies Components Project Photo Gallery